<?xml version="1.0" encoding="utf-8" standalone="no"?>
<!DOCTYPE article SYSTEM "http://www.adv-radio-sci.net/inc/ars/copernicus.dtd">
<article language="en">
	<journal>
		<journal_title>Advances in Radio Science</journal_title>
		<journal_url>www.adv-radio-sci.net</journal_url>
		<issn>1684-9965</issn>
		<eissn>1684-9973</eissn>
		<volume_number>6</volume_number>
		<volume_title>Kleinheubacher Berichte 2007</volume_title>
		<publication_year>2008</publication_year>
	</journal>
	<doi>10.5194/ars-6-27-2008</doi>
	<article_url>http://www.adv-radio-sci.net/6/27/2008/</article_url>
	<abstract_html>http://www.adv-radio-sci.net/6/27/2008/ars-6-27-2008.html</abstract_html>
	<fulltext_pdf>http://www.adv-radio-sci.net/6/27/2008/ars-6-27-2008.pdf</fulltext_pdf>
	<start_page>27</start_page>
	<end_page>30</end_page>
	<publication_date>2008-05-26</publication_date>
	<article_title content_type="html">Calibration-measurement unit for the automation of vector network analyzer measurements</article_title>
	<authors>
		<author numeration="1" affiliations="1">
			<name>I. Rolfes</name>
			<email>rolfes@hft.uni-hannover.de</email>
		</author>
		<author numeration="2" affiliations="2">
			<name>B. Will</name>
		</author>
		<author numeration="3" affiliations="2">
			<name>B. Schiek</name>
		</author>
	</authors>
	<affiliations>
		<affiliation numeration="1" content_type="html">Institut für Hochfrequenztechnik und Funksysteme,  Leibniz Universität Hannover, Appelstraße 9A, 30167 Hannover, Germany</affiliation>
		<affiliation numeration="2" content_type="html">Institut für Hochfrequenztechnik,  Ruhr-Universität Bochum, Universitätsstraße 150, 44801 Bochum, Germany</affiliation>
	</affiliations>
	<abstract content_type="html">With the availability of multi-port vector network analyzers, the
need for automated, calibrated measurement facilities increases.
In this contribution, a calibration-measurement unit is presented
which realizes a repeatable automated calibration of the
measurement setup as well as a user-friendly measurement of the
device under test (DUT). In difference to commercially available
calibration units, which are connected to the ports of the vector
network analyzer preceding a measurement and which are then
removed so that the DUT can be connected, the presented
calibration-measurement unit is permanently connected to the ports
of the VNA for the calibration as well as for the measurement of
the DUT. This helps to simplify the calibrated measurement of
complex scattering parameters. Moreover, a full integration of the
calibration unit into the analyzer setup becomes possible. The
calibration-measurement unit is based on a multiport switch setup
of e.g. electromechanical relays. Under the assumption of symmetry
of a switch, on the one hand the unit realizes the connection of
calibration standards like one-port reflection standards and
two-port through connections between different ports and on the
other hand it enables the connection of the DUT. The
calibration-measurement unit is applicable for two-port VNAs as
well as for multiport VNAs. For the calibration of the unit,
methods with completely known calibration standards like SOLT
(short, open, load, through) as well as self-calibration
procedures like TMR or TLR can be applied.</abstract>
	<references>
		<reference numeration="1" content_type="text"> Engen, G. F. and Hoer, C. A.: Thru-Reflect-Line: An improved technique for calibrating the dual six port automatic network analyzer, IEEE T. Microw. Theory, 27, 987&amp;ndash;993, 1979. </reference>
		<reference numeration="2" content_type="text"> Eul, H. J. and Schiek, B.: A Generalized Theory and New Calibration Procedures for Network Analyzer Self-Calibration, IEEE T. Microw. Theory, 39, 724&amp;ndash;731, 1991. </reference>
		<reference numeration="3" content_type="text"> Henkel, A.: Unrivaled &amp;ndash; up to eight test ports in a single unit, News from Rohde &amp; Schwarz, 189, 26&amp;ndash;29, 2006. </reference>
		<reference numeration="4" content_type="text"> Krekels, H.-G.: AutoKal: Automatic Calibration of Vector Network Analyzer ZVR, Rohde &amp; Schwarz Application Note 1EZ30 IE, 1996. </reference>
		<reference numeration="5" content_type="text"> Krekels, H.-G. and Schiek, B.: A novel Procedure for an automatic Network-Analyzer Calibration, IEEE T. Instrum. Meas., 44, 291&amp;ndash;294, 1995. </reference>
	</references>
</article>