<?xml version="1.0" encoding="utf-8" standalone="no"?>
<!DOCTYPE article SYSTEM "http://www.adv-radio-sci.net/inc/ars/copernicus.dtd">
<article language="en">
	<journal>
		<journal_title>Advances in Radio Science</journal_title>
		<journal_url>www.adv-radio-sci.net</journal_url>
		<issn>1684-9965</issn>
		<eissn>1684-9973</eissn>
		<volume_number>2</volume_number>
		<volume_title>Kleinheubacher Berichte 2003</volume_title>
		<publication_year>2004</publication_year>
	</journal>
	<doi>10.5194/ars-2-27-2004</doi>
	<article_url>http://www.adv-radio-sci.net/2/27/2004/</article_url>
	<abstract_html>http://www.adv-radio-sci.net/2/27/2004/ars-2-27-2004.html</abstract_html>
	<fulltext_pdf>http://www.adv-radio-sci.net/2/27/2004/ars-2-27-2004.pdf</fulltext_pdf>
	<start_page>27</start_page>
	<end_page>32</end_page>
	<publication_date>2005-05-27</publication_date>
	<article_title content_type="html">A novel quasi-peak-detector for time-domain EMI-measurements</article_title>
	<authors>
		<author numeration="1" affiliations="1">
			<name>F. Krug</name>
		</author>
		<author numeration="2" affiliations="1">
			<name>S. Braun</name>
		</author>
		<author numeration="3" affiliations="1">
			<name>P. Russer</name>
		</author>
	</authors>
	<affiliations>
		<affiliation numeration="1" content_type="html">Institute for High-Frequency Engineering, Technische Universität München, Arcisstrasse 21, 80333 Munich, Germany</affiliation>
	</affiliations>
	<abstract content_type="html">In this paper, an advanced ultra-fast, broadband
time domain EMI measurement system is described. Measurements
were performed in the 30–1000MHz range. The
digital signal processing of EMI measurements allows to
emulate in real-time the modes of conventional analogous
equipment, e.g. Peak-, Average-, RMS- and Quasi-Peak-
Detector. With the presented time domain measurement system
the measurement time can be reduced by a factor of
10. A novel signal recording routine for time-domain EMI
(TDEMI) measurements and Quasi-Peak-Detection is described.
Measurement results obtained from the investigation
of a drillmachine, monitor and laptop obtained with the timedomain
electromagnetic interference (TDEMI) measurement
system are discussed. The results obtained with the described
system have been compared with measurements performed
with a conventional EMI receiver.</abstract>